Default module settings, Cli setup, Proper boot sequence – Enterasys Networks 8000/8600 User Manual
Page 86: Common errors, Helpful cli commands for debugging
Installing the Hardware
74
Enterasys X-Pedition 8000/8600 Getting Started Guide
SSR-GTX32-04
SSR-GTX32-02
9.0.0.0
Note: The SSR-GTX32-02 line card does not
support 10/100 Mbps traffic.
Default Module Settings
The default mode for each port on the
X-Pedition 8000/8600X-Pedition is:
Full duplex/ 1000 mbs/ autonegotiation on
To view the current mode for a particular port, enter
the following (where x is the chassis slot that
contains the line card and y is a specific port number
on the card):
xp# port show port status gi.x.y
CLI Setup
Enter the following commands at the CLI before
implementing any configurations.
1.
Enable —> Configure —>
2.
Once you reach the configuration prompt, you
can configure the module
using CLI commands
as described in the X-Pedition CLI manual.
Enter the ? character to view the options
available to you in configuration mode.
Proper Boot Sequence
•
Offline LED lights at power-up.
•
Port LEDs flicker briefly during system boot while
ports initialize.
•
Online LED turns on once module is active.
Common Errors
•
The X-Pedition is not powered up.
•
The module is not properly seated in the slot.
•
Connectors on both ends of the cable are not properly
engaged. The copper cable did not click into place or
is not properly seated.
Helpful CLI Commands for Debugging
•
System show hardware
•
System show version
•
System show bootlog
SSR-HSSI-02-CK
8.3.0.0
CLI Setup
Enter the following command at the CLI before
implementing any configurations.
1.
Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #
2.
You may now begin configuring ports on the
SSR-HSSI-02-CK. Refer to the Enterasys
X-Pedition Command Line Interface Reference
Manual for details.
Proper Boot Sequence
•
Firmware loads.
•
The control module for the chassis should indicate
that the SSR-HSSI-02-CK was detected and is
operating correctly.
•
The Online LED will turn on and remain lit (no other
LEDs should illuminate during module power-up).
Common Errors
•
The SSR-HSSI-02-CK is not inserted properly or
seated completely in the chassis
•
Connectors for the connected lines are not seated
properly.
•
The CM does not connect to a terminal through a
console port.
Helpful CLI Commands for Debugging
•
System show hardware
•
System show version
•
Port show port status gi.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).
•
System show boot log
Table 19. Line card installation notes (Continued)
Minimum
Firmware
Restrictions
Special Instructions