Power-on diagnostics error messages (continued)

Error message

DISPLAY SWITCH IS

SET INCORRECTLY

Action

Jumper J5 conflicts with the video options in the

SETUP program. See Chapter 2 of the User’s Guide

for correct jumper settings and Chapter 2 of the

Setup Guide for instructions on running SETUP.

DISPLAY TYPE HAS

CHANGED SINCE

LAST BOOT

The display adapter has been changed. Run

SETUP. See Chapter 2 of the Setup Guide.

FLOPPY DISK

The system was unable to detect a diskette drive

CONTROLLER ERROR controller.

OR NO

CONTROLLER

If you have no diskette drive, run SETUP and select

PRESENT

none for both diskette drives.

If you have at least one diskette drive, see

,, Diskette Drive Problems. ”

FLOPPY DISK TYPE IS

The installed diskette drive does not match the

SET INCORRECTLY

CMOS definition. See “Diskette Drive Problems.”

OR DRIVE ERROR

HARD DRIVE

The system was unable to detect the hard disk

CONTROLLER

drive controller. See “Hard Disk Problems,”

DIAGNOSTICS ERROR

HARD DRIVE SECTOR

Your hard disk drive may be damaged. Contact

VERIFY ERROR

your Authorized Epson Servicer.

KEYBOARD ERROR

Your keyboard may not be connected correctly,

OR NO KEYBOARD

See “Keyboard Problems.”

PRESENT

MEMORY ERROR

DURING MEMORY

TEST

Your SIMMS may not be installed correctly. See

“Memory Module Problems.”

NON-SYSTEM DISK

OR DISK ERROR

The system cannot boot from the diskette. Make

sure the diskette is bootable and see

*Diskette Problems. ”

Troubleshooting 6-5