Power-on diagnostics error messages (continued), Troubleshooting 6-5 – Epson Endeavor User Manual
Page 134
Power-on diagnostics error messages (continued)
Error message
DISPLAY SWITCH IS
SET INCORRECTLY
Action
Jumper J5 conflicts with the video options in the
SETUP program. See Chapter 2 of the User’s Guide
for correct jumper settings and Chapter 2 of the
Setup Guide for instructions on running SETUP.
DISPLAY TYPE HAS
CHANGED SINCE
LAST BOOT
The display adapter has been changed. Run
SETUP. See Chapter 2 of the Setup Guide.
FLOPPY DISK
The system was unable to detect a diskette drive
CONTROLLER ERROR controller.
OR NO
CONTROLLER
If you have no diskette drive, run SETUP and select
PRESENT
none for both diskette drives.
If you have at least one diskette drive, see
,, Diskette Drive Problems. ”
FLOPPY DISK TYPE IS
The installed diskette drive does not match the
SET INCORRECTLY
CMOS definition. See “Diskette Drive Problems.”
OR DRIVE ERROR
HARD DRIVE
The system was unable to detect the hard disk
CONTROLLER
drive controller. See “Hard Disk Problems,”
DIAGNOSTICS ERROR
HARD DRIVE SECTOR
Your hard disk drive may be damaged. Contact
VERIFY ERROR
your Authorized Epson Servicer.
KEYBOARD ERROR
Your keyboard may not be connected correctly,
OR NO KEYBOARD
See “Keyboard Problems.”
PRESENT
MEMORY ERROR
DURING MEMORY
TEST
Your SIMMS may not be installed correctly. See
“Memory Module Problems.”
NON-SYSTEM DISK
OR DISK ERROR
The system cannot boot from the diskette. Make
sure the diskette is bootable and see
*Diskette Problems. ”
Troubleshooting 6-5