Operation

3.8 Factory Default Values

Your RD Series inverter/charger uses default values for the adjustable settings (see Table 3-2) that

are adequate for most installations. If some of your operating parameters need to be changed from

the default values, the optional ME-RC50 remote control can be used to make those changes. To

help you determine if you need the ME-RC50 remote display, information on the inverter/charger

settings that can be changed is provided below. The settings, once programmed, are saved in the

remote’s non-volatile memory and are preserved until changed – even if DC power to the inverter

is lost (as long as the ME-RC50 remote is connected). For information on the full range of settings

for each function, refer to the ME-RC50 Owner’s Manual at www.magnumenergy.com.

Shore: This setting ensures the inverter AC loads receive the maximum current available

from the utility power or generator. When the total current used to power the AC loads

and to charge the batteries begins to approach the “Shore” setting, the current that was

used for charging the batteries will automatically be reduced.

01 Search Watts: This setting allows you to turn off the power-saving Search Mode circuitry

or adjust the power level at which the inverter will “wake up” and start inverting.

02 LowBattCutOut: This setting determines when the inverter will turn off based on

low battery voltage. The inverter turns off automatically after the battery voltage has

been below this setting for more than one minute. This protects the batteries from over-

discharge and the AC loads from unregulated power (brown-outs).

03 Batt AmpHrs: This setting allows the user to input the battery bank size in amp hours,

which tells the charger how long to charge the batteries in the Absorb Charge stage.

04 Battery Type: Sets the type of batteries being used in the system; this information

tells the charger what voltage level to use to charge the batteries.

05 Charge Rate: This setting can be used to turn off the charger, limit the amount of

current that the charger can use (leaving more current available to power loads); or, to

ensure small battery banks are not overheated because of a too high charge rate.

06 VAC Dropout: Sets the minimum AC voltage that must be present on the AC input

before the unit transfers from Standby Mode to Inverter Mode. This protects the AC loads

from utility power outages and brown-outs.

Using the ME-RC50 remote also provides the following features:

allows you to enable an equalize charge for certain battery types

displays inverter/charger’s operating status

provides fault information for troubleshooting

Table 3-2, Inverter/Charger Default Values

Adjustable Settings

Default Values

Shore 30

amps

01 Search Watts

5 watts

02 LowBattCutOut

10 VDC (12-volt models), 20 VDC (24-volt models)

03 Batt AmpHrs

600 Amp Hours (Absorb Time = 120 minutes)

04 Battery Type

Flooded - Liquid Lead Acid

05 Charge Rate

100%

06 VAC Dropout

80 VAC