beautypg.com

Magnum Energy RD Series User Manual

Page 38

background image

Page 32

©

2010 Magnum Energy, Inc.

Installation

T h is ele c tric al s y s te m is e qu ipp e d w ith a n A u to m atic
G e n era to r S ta rting (A G S ) d e v ic e a n d/o r a n in v e rte r.
D is c o nn e c t a ll A C a n d D C p ow er to th e A G S a n d /o r
in v e rte r b e fo re p erfo rm in g a n y s e rv ic e to the e lectric a l
s y ste m . F ailu re to d o s o c an re su lt in s h oc k cau s ing
serio us i n jury or de ath .

P N : 62-0002 R ev A

2.8 Final

Inspection

Verify all cables/conduit runs are secured with wire ties or other non-conductive fasteners to

prevent chafi ng, or damage from movement and vibration.
Verify strain reliefs or grommets are in place to prevent damage to the wiring or conduit where

it passes through walls or other openings.
Verify all AC connections are correct and torqued to a maximum of 16 in lbf (1.8 N-m).
Replace the covers on the main electrical/distribution panel.
Replace the chassis access cover.
Verify the inverter’s front panel switch is in the OFF position.

Info: If required by code, have the installation inspected by an electrical inspector.

2.9 Functional

Test

After all electrical connections

to the inverter, batteries, AC source, and sub-panel

have been

completed, follow these steps to test the installation and the inverter operation.

CAUTION: Use a multimeter to verify the correct DC voltage for your particular inverter

model (i.e., 24-volt battery bank for a 24-volt inverter), and to ensure the polarity of the

battery voltage is correct (battery positive connected to inverter positive, and battery

negative connected to inverter negative).

1. Apply battery power to the inverter by closing the DC circuit breaker or inserting a fuse. The

inverter will remain OFF, but the green status indicator on the front of the inverter will quickly

blink once to indicate that DC power has been connected and is ready to be turned on.

2. Prior to turning on the inverter, make sure all AC loads (e.g., appliances) are NOT connected

to the inverter’s output or to any AC outlets powered by the inverter.

3. Lightly press and release the inverter’s ON/OFF switch to turn the inverter ON. Verify the

inverter’s status indicator is blinking – indicating the inverter is ON.

4. Connect a small light bulb no larger than 75 watts to the inverter output and verify it comes on

and shines normally. DO NOT connect anything but a light bulb until all wiring and voltages are

confi rmed to be correct.

1.

2.

3.
4.
5.
6.

2.7 Inverter

Notifi cation Requirements

A warning label as shown in Figure 2-19 is provided to inform all personnel that an inverter is

installed in your electrical system. Affi x this label in a clearly visible location by the electrical panel

that is being powered by the inverter. This is because it might be falsely assumed that the panel is

no longer “hot” after the AC power has been shut off, when power may actually still be available

due to the inverter automatically powering the panel.

Figure 2-19, Warning Label

This electrical system is equipped with an Automatic

Generator Starting (AGS) device and/or an inverter.
Disconnect all AC and DC power to the AGS and /or

inverter before performing any service to the electrical
system. Failure to do so can result in shock causing

serious injury or death . PN: 62-0002 Rev A

This manual is related to the following products: