beautypg.com

Magnum Energy RD Series User Manual

Page 45

background image

©

2010 Magnum Energy, Inc

Page 39

Operation

3.7 Inverter

Startup

ON/OFF Switch - The inverter can be turned on and off by lightly pressing and releasing the Power

ON/OFF switch on the front of the inverter (see Figure 3-5). When the inverter is fi rst connected

to the batteries, or when its automatic protection circuit has turned the inverter off, the ON/OFF

switch will need to be pressed to start the unit (or reset per Section 4.3). Once the inverter has

been turned on, pressing the Power ON/OFF switch alternately turns the inverter on and off.

WARNING: The Power ON/OFF control switch does not turn on or off the charger

feature. If AC power (utility power or generator) is connected and qualifi ed on the AC

input, this AC power will also be available on the AC output and is not controlled by

the Power ON/OFF switch.

Status LED Indicator - The status indicator is a green LED (Light Emitting Diode) that provides

information on the operational mode of the inverter. Watch this indicator (see Figure 3-5) for at least

10 seconds to determine the inverter’s operational condition from the information below:

Off - Indicates the inverter is off; there is no AC power (inverter, utility power, or generator)

at the inverter’s output terminals. If the LED stays off after pressing the ON/OFF switch,

there is a “fault condition” such as low battery, high battery, overload, over-temperature,

or an internal fault. Refer to the Troubleshooting section to help diagnose/clear the fault

condition.

Slow fl ash (blinks on once every 8 seconds) - Indicates fl oat charging; the inverter is in

Standby Mode (the external AC power that is connected to the inverter’s input is passing

through the inverter and is powering the AC loads connected to the inverter’s output).

Medium fl ash (blinks on once every second):
When AC power is not connected to inverter input - Indicates the inverter is on and using

energy from the battery. The inverter is either: 1) Inverting - providing full power to the

loads connected to the inverter; or, 2) Searching - conserving power and waiting for a load

to be turned on that meets or exceeds the search watts parameter (5 watts is the inverter

default setting).

When AC power is connected to inverter input - Indicates absorb charging; the inverter is

in Standby Mode (the external AC power that is connected to the inverter’s input is passing

thru the inverter and is powering the AC loads connected to the inverter’s output).

On (solid) - Indicates bulk charging; the inverter is in Standby Mode (the external AC

power that is connected to the inverter’s input is passing thru the inverter and is powering

the AC loads connected to the inverter’s output).

Figure 3-5, Power Switch and Status Indicator

Charging/Inverting

Status LED indicator

Power ON/OFF

pushbutton switch

This manual is related to the following products: