Introduction

Figure 1-3, Left Side Features

The left side of the RD Series is equipped with the following features (see Figure 1-3):

13

Exhaust Air Vent - ventilation openings that allow heated air to be removed by the

internal cooling fan.

14

Model/Serial Number Label - includes model/serial number information, date of

manufacture, and inverter and charger specifi cations. See the RD Specifi cations in

Appendix A for more information and the different models that are available.

15

AC Access Cover - provides access to the internal AC wiring terminal block. This terminal

block is used to hardwire all inverter AC input and output wiring connections. Remove the

two screws to access the AC wiring terminal block.

16

Input Circuit Breaker - this circuit breaker protects the unit’s internal charger wiring

and pass-thru relay while in Standby Mode. This circuit breaker will pop out when it

opens. Press in to reset. This input circuit breaker is not branch-circuit rated, therefore,

branch-circuit rated breakers must be installed in the inverter’s input wiring.

CAUTION: The inverter’s internal AC transfer relay is rated for 30 amps per leg. The

pass-thru current must be no greater than 30 amps per leg or damage to the relays

may occur.