Appendix B - Battery Information

Parallel Wiring
Wiring the batteries in parallel increases the total run time the batter-

ies can operate the AC loads. A parallel connection combines overall

battery capacity by the number of batteries in the string. Even though

there are multiple batteries, the voltage remains the same. In the ex-

ample below (Figure 15), four 12 VDC/100 AHr batteries are combined

into a single 12 VDC/400 AHr battery bank.

Series-Parallel Wiring
A series-parallel confi guration increases both voltage (to match the

inverter’s DC requirements) and capacity (to increase run time for

operating the loads) using smaller, lower-voltage batteries. In the ex-

ample below (Figure 16), four 6 VDC/200 AHr batteries are combined

into two strings resulting in a 12 VDC/400 AHr battery bank.

Figure 15, Parallel Battery Wiring

Figure 16, Series-Parallel Battery Wiring

34

12 volt battery bank (total capacity = 400 AHrs)

overcurrent

protection

12 volts

(100 AHrs )

12 volts

(100 AHrs )

12 volts

(100 AHrs )

12 volts

(100 AHrs )

To

12 VDC

Inverter

overcurrent

protection

String 2

String 1

12 volt battery bank (total capacity = 400 AHrs)

To

12 VDC

Inverter

6 volts

(200 AHrs)

6 volts

(200 AHrs)

6 volts

(200 AHrs)

6 volts

(200 AHrs)