Table 3, Wire Color to AC Wire Connection

Wire color (label)

Wire connection

Black (HOT IN)

Hot In

White (NEUT IN)

Neutral In

Red (HOT OUT)

Hot Out

White with black

stripe (NEUT OUT)

Neutral Out

AC Ground

Green (GROUND)

AC IN and AC OUT Ground

AC IN

AC OUT

Neutral to Safety Ground Bonding

Electrical safety standards for wiring mobile (RV, boat, or truck)

installations require the AC source (inverter, shore power, or a generator)

to have the neutral conductor tied to ground. These standards also

require that the AC neutral be connected to safety ground in only one

place at any time (often called a “bond”). If more than one bond is

established, currents can circulate between neutral and ground and cause

ground-loop currents. These “ground-loops” can trip GFCIs and cause an

electric shock hazard.
In mobile installations there may be multiple AC sources, which means

there is the potential of having multiple neutral to ground connections.

Therefore, you must ensure that the inverter does not also connect

neutral-to-ground while the other AC source is powering the inverter

loads. While inverting, the MM inverters use an internal relay that

automatically connects the AC neutral output terminal to the vehicle/

boat’s ground. However, when an external AC source is connected,

another neutral-to-ground connection is introduced in the system. When

the MM Series is connected to this external AC source, the internal relay

automatically opens the neutral-to-ground connection. This design keeps

two neutral-to-ground connections from occurring at the same time.

AC Wiring Connections
For all hardwired inverter models, the AC input and output wiring is per-

formed in the AC wiring compartment. This compartment is located on

the top panel (see Figure 2, Item 8). If installed, remove the two Phillips

screws on the cover to access the AC wiring compartment and locate the

inverter’s AC wiring. There is a label located in the AC access compart-

ment with information on which wires are used for the AC input and out-

put. You can also refer to Table 3 to match the inverter’s AC wires to the

appropriate AC wire connection.

AC Wiring

This section describes the required AC wire size and the overcurrent

protection needed. It also provides information on how to make the AC

connections.

17

2.0 Installation

This manual is related to the following products: