beautypg.com

Magnum Energy MM612 Inverter User Manual

Page 36

background image

©

2010 Magnum Energy, Inc.

30

Appendix A - Remote Control and Monitoring

ON/OFF Switch

The ON/OFF Switch is a momentary push-button switch that duplicates

the ON/OFF switch on the inverter. This switch also allows additional

changes to be made while in the Invert or Charge Mode.
When the inverter is fi rst connected to the batteries, the inverter and

remote go through an internal 10 seconds start-up test. After this test

is completed, the ON/OFF switch can be pressed to turn on the inverter.

Once the inverter has been turned on, momentarily pressing the ON/OFF

switch alternately turns the inverter On/Standby and Off.
On models with the Search Mode function, the ON/OFF switch can be used

to enable or disable the Search Mode. While in the Invert Mode, pressing

and holding this switch for three seconds causes the Search Mode to

alternate between Disabled (inverter always on – indicated by the INVERT

LED indicator always on) and 5W (inverter is looking for at least a 5 watt

load to turn on and start inverting – indicated by the INVERT LED indicator

blinking once a second).
On models with the battery charger feature, this switch can also be

used to put the charger in standby (disables the charger) so that all the

incoming power can be used exclusively for the AC loads. To put the

charger in standby, press and hold the ON/OFF switch for three seconds

(you must be in the Charge Mode). When this happens, the charging

indicators (BULK, ABSORB and FLOAT) will go off. To activate the charger,

press and hold the ON/OFF switch for three seconds again. When the

charger is again activated, one of the charging indicators will come on to

show the current charge stage.

WARNING:

When any external AC power is passing

through the inverter and present on the output, pressing

the ON/OFF switch will not remove this AC power on the

inverter’s output.

Monitoring the LED Indicators

MM-R and MM-RC Remotes

The three LED indicators on the left side of both the MM-R and MM-RC

remotes (

s

ee

Figure 13)

will show you the operating status of the

MM

Series inverter.

Monitor the indicators to determine the mode of operation:

INVERT (green) -
• On (solid)

- and the AC IN LED indicator is Off. The inverter is On. It is using

energy from the battery to supply AC power to the loads connected to

the inverter.
- and the AC IN LED indicator is On (solid). The inverter is in Standby.

The external AC power (utility/shore power or generator) connected

to the inverter’s input is passing through the inverter to power the AC

loads. The inverter will automatically turn on to power the AC loads if

the external AC power is lost or disconnected.

• Blinks On (once every second) - The inverter is in Search Mode. The AC

load is below 5 watts (Search Watts default setting).