15. AC output connection - AC knockout (output) for hardwiring.
16. AC input connection

- AC knockout (input) for hardwiring.

17. DC Ground terminal - this connection is used to tie the exposed

chassis of the inverter to the DC grounding system. This terminal ac-

cepts CU/AL conductors from #14 AWG to #6 AWG.

Battery Temperature Sensor (Battery Charger Models Only)

A plug-in external Battery Temperature Sensor (BTS) is provided

for units with the battery charger feature. When installed, the BTS

automatically adjusts the battery chargers BULK, ABSORB, and

FLOAT voltage set-points based on temperature for better charging

performance and longer battery life. If the temperature sensor is NOT

installed and the batteries are subjected to large temperature changes,

the battery life may be shortened.