10.2 External Reset Input Signal and Resetting Output Signals
The external reset (ERS) is the input signal to reset the PCNC.
When the ERS input signal is “closed”, the PCNC stops the entire operation and closes the
resetting output signal for one second.
The output signals are “opened” with the exception as shown in Table 10.1.
Table 10.1 Output Signals which are “Closed”
IMPORTANT!
When the ERS input is “closed”, the CNC is in the label skip state. In this case, however, the tape
is not rewound; although, the memory is rewound.
Label skip:When the PCNC is in the label skip state, the information having been read until the
first end of the block code is read after power ON or reset, is ignored. There is no
parameter to cancel the label skip state.
External Reset Input Signal
ERS
#30041
Resetting Output Signal
RSTS
#35001
Output Signal
Name
Output when ERS Input is “Closed”
AUT, MAN
ZPX to ZP5
2ZPX to 2ZP5
3ZPX to 3ZP5
4ZPX to 4ZP5
5ZPX to 5ZP5
4NGC, 5NGC
The previous state is maintained.
RSTS
“Closed” while ERS input is “closed”,
and “closed” for one second after the
ERS input is changed from “closed” to
“opened”.
ALMS
Remains “opened” unless
the cause of alarm remains
SDO0 to SDO23
The previous state is maintained.
UO0 to UO31
The previous state is maintained.