(4) Stopped Output Signal
If the automatic operation start input “ST” is “closed” and then “opened” with the automatic
operation stop input “*SP” closed, the stopped output “SPL” is opened and automatic opera-
tion is restarted.
The running ouput “STL” is closed.
Fig. 6.4 Time Chart of ST and *SP Input Signals and STL and SPL Output Signals
IMPORTANT
1. The automatic operation start (ST) and automatic stop (*SP) input signals must be “closed” or
“opened” for more than 100msec. If it is less than 100 msec., such input signals may be
ignored.
2. If automatic operation stop (*SP) input signal is “closed” in the state where the CNC is wait-
ing for the completion of M,S,T or B commands (waiting for “FIN” input), the automatic
stopped (SPL) output signal is turned ON. If M,T or B command complete (FIN) input signal
is “opened”, the PCNC enters the automatic operation stopped state.
3. The STL is opened in the single-block stop state.
4. The STL stays closed in the alarm state (ALM).
Close
Open
STP
Close
Open
STL
Close
Open
*SP
Close
Open
SPL
PCNC status
Halt Running Halt Running