9 - 5

YASNAC PCNC I/O Signal Function Manual Chapter 9: Automatic Support Functions

9.5 External Data Input/Output Signals

(1) External Data Input/Output Function

(a) External work number search input signal

By specifying any of the following proram numbers externally in BCD, the required

work number can be selected.

Program numbers: 1 to 99999

(b) External tool offset input signal

It is possible to correct the offset data (tool length offset data, tool radius offset data)

by using the external data input signal.

(c) External workpiece coordinate system shift input signal

It is possible to correct the shift amount of workpiece coordinate systems by using

the external data input signal.

By inputting the correction data for the individual axes, the input data is added to the

present shift data of G54 to G59 to obtain the new shift data.

(2) Input Signals Used for External Data Input

(a) External data input signal

The external data input signal is used for the workpiece number input signal, offset

data input signal and workpiece coordinate system shift data input signal.

Table 9.1 External Data Input Signals

External Data Input Signal

ED0 to ED31

#30300 to #30337

External Data Selection Input Signal

EDSA to EDSD

#30340 to #30343

External Data Axis Selection Input Signal

EDAS0 to EDAS2

#30344 to #30346

External Data Selection Strobe Input Signal

EDCL

#30347

External Data Input Complete Output Signal

ER END to ES END

#35045 to #35046

External Data Input Signals

ED7

ED6

ED5

ED4

ED3

ED2

ED1

ED0

ED15

ED14

ED13

ED12

ED11

ED10

ED9

ED8

ED23

ED22

ED21

ED20

ED19

ED18

ED17

ED16

ED31

ED30

ED29

ED28

ED27

ED26

ED25

ED24