Yaskawa YASNAC PC NC I/O Signal Function Manual User Manual
Page 76

9 - 5
YASNAC PCNC I/O Signal Function Manual Chapter 9: Automatic Support Functions
9.5 External Data Input/Output Signals
(1) External Data Input/Output Function
(a) External work number search input signal
By specifying any of the following proram numbers externally in BCD, the required
work number can be selected.
Program numbers: 1 to 99999
(b) External tool offset input signal
It is possible to correct the offset data (tool length offset data, tool radius offset data)
by using the external data input signal.
(c) External workpiece coordinate system shift input signal
It is possible to correct the shift amount of workpiece coordinate systems by using
the external data input signal.
By inputting the correction data for the individual axes, the input data is added to the
present shift data of G54 to G59 to obtain the new shift data.
(2) Input Signals Used for External Data Input
(a) External data input signal
The external data input signal is used for the workpiece number input signal, offset
data input signal and workpiece coordinate system shift data input signal.
Table 9.1 External Data Input Signals
External Data Input Signal
ED0 to ED31
#30300 to #30337
External Data Selection Input Signal
EDSA to EDSD
#30340 to #30343
External Data Axis Selection Input Signal
EDAS0 to EDAS2
#30344 to #30346
External Data Selection Strobe Input Signal
EDCL
#30347
External Data Input Complete Output Signal
ER END to ES END
#35045 to #35046
External Data Input Signals
ED7
ED6
ED5
ED4
ED3
ED2
ED1
ED0
ED15
ED14
ED13
ED12
ED11
ED10
ED9
ED8
ED23
ED22
ED21
ED20
ED19
ED18
ED17
ED16
ED31
ED30
ED29
ED28
ED27
ED26
ED25
ED24