Yaskawa YASNAC PC NC I/O Signal Function Manual User Manual
Page 84

9 - 13
YASNAC PCNC I/O Signal Function Manual Chapter 9: Automatic Support Functions
9.9 Direct Processing Signal Monitor Output Signal
The direct processing signal monitor output signal outputs the status of the direct
IN signal (DIN0), which is directly read from the CN01 of JCP03 board to the NC.
The relationship between the direct IN common input signal and the parameters
setting is indicated below.
Table 9.5 Relationship between Direct IN Signal and Parameter Setting
For HIN1 (#35140), the open status can be changed by the setting of the following
parameter.
pm5010 D5 = 0: Open by “0” “1”
pm5010 D5 = 1: Open by “1” “0”
9.10 Position Monitor Output Signal
The function monitors the position of the axis which is specified by the parameter
to detect if it is within the preset range.
This signal is “closed” while the axis specified by the following parameters is
within the preset range. It is “opened” if the axis moves beyond the specified
range.
Direct Processing Signal Monitor
Output Signal
HIN1
#35140
Common Input
pm5001 D0
1
24 V common, NO
0: Negative logic
2
24 V common, NC
1: Positive logic
3
0 V common, NO
1: Positive logic
4
0 V common, NC
0: Negative logic
Position Monitor Output Signal
MPON1 to PMON10
#36340 to #363451