9 - 3

YASNAC PCNC I/O Signal Function Manual Chapter 9: Automatic Support Functions

9.4 Tool Life Management Input/Output Signals

(1) Tool Skip Input Signal

If the tool skip input signal is “closed” during the exceution of the tool life management
function, the life status of the tool presently used is forcibly set as “skipped”.

This signal is also used to skip the tools in the specified groups. By setting these tool
group numbers by te tool skip number input signals (TGN0 to TGN7), the tools in these
groups are skipped when the tool skip input signal (TLSKP) is “closed” under the con-
dition that the parameter pm4029D1 = 1.

(2) Tool Life Count Ignore Input Signal

Tool life counting is suspended when this signal is “closed” during the execution of the
tool life management function.

(3) New Tool Selection Output Signal

When a new tool is selected in a tool group and if the status of use of
the new tool is “0”, this signal is “closed” at the same time that a T code
is output.

(4) Tool Change Output Signal

If all tools in a tool group have been used-up to life expiration during the
execution of the tool life management function, this signal is “closed”.

Tool Skip Input Signal

TLSKP

#30126

Tool Life Count Ignore Input Signal

TLCTN

#30127

Tool Skip Group Number Input Signal

TGN0 to TGN7

#30250 to #30257

New Tool Selection Output Signal

TLCHB

#35086

Tool Change Output Signal

TLCHA

#35087

Life Expiration Check Request Input Signal

TLCH

#30124

Life Expiration Group Number Input Signal

TLTGN0 to TLTGN7

#30230 to #30237

Life Expiration Check Complete Output Signal

TLCEND

#35085

Life Expired/Not-Expired Output Signal

TLANS

#35084