2 ethernet/ip transmission definition, 1 network parameter tab page – Yaskawa JAPMC-CM2304-E User Manual
Page 50

4.2 EtherNet/IP Transmission Definition
4.2.1 Network Parameter Tab Page
4-4
4.2 EtherNet/IP Transmission Definition
The EtherNet/IP Transmission Configuration window has four tab pages, namely Network Parameters, Connection
List, I/O Status and Module Information. Select the appropriate tab page to perform setting and monitoring.
4.2.1 Network Parameter Tab Page
On the Network Parameter tab page, set the network parameters required to perform EtherNet/IP communication. The
following explains the details of the network parameter setting.
After changing the setting on the Network Parameter Setting tab page, save the definition data by selecting File -
Save to Flash from the Main Menu.
Configuration Information
Displays the 263IF-01 Module configuration information. The configuration information is the same as the information
displayed in the Module Details area in the Module Configuration window.
RACK#: The rack number of the rack in which the 263IF-01 is defined.
Slot#: The slot number of the slot in which the 263IF-01 is defined.
CIR#: The circuit number of the EtherNet/IP port on the 263IF-01.
When the MSG-SND function is used, set the circuit number displayed here for Circuit Number.
Network Parameters
IP Address
Set the IP address of the local station.
There are four 8-bit fields delimited by periods (.). Input a decimal number for each field.
Contact the network administrator for the available IP address.
Do not use an address already set for another station. If an IP address is duplicated, the Network Status will be
set to IP Duplicated on the Module Information screen (refer to page 4-16). If this happens, the module can-
not join the network.
Subnet Mask
Enter the subnet mask for the IP address of the local station.
The range that can be entered in fields 1 to 3 is 0 to 255. The range that can be entered in field 4 is 0 to 254.
1
2
3
4
5
Configuration Information
1
Field No. 4: 001 to 254
Field No. 2: 000 to 255
Field No. 1: 000 to 255 (excluding 127)
Field No. 3: 000 to 255
2