3.3 Setting the Communication Manager

3.3.2 Setting the Communication Manager

3-11

3

Mounting and Starting the Module

( 2 ) Setting the Ethernet Communication Port

1.

In the Communication Manager window, double-click the number in the Logical PT column of a line
which has not been set (In the following example, Line 2 and subsequent lines have not been set.) to
view the Logical Port Setting dialog box.

2.

Select Ethernet or CP-218 under Port Kind in the Logical Port Setting dialog box and click the
Detail button.

Œ

Ethernet and CP-218 require the same communication specifications. Either can be set for EtherNet/IP
(10BASE-T) communication.

The CP-218 Port Setting dialog box will be displayed.

3.

Enter the IP address of computer and click OFF for Default. Leave the other items on their default set-
tings. Click the OK button to close the dialog box.

4.

Click the OK button in the Logical Port Setting dialog box. The display will return to the Communica-
tion Manager
window. Confirm that CP-218 (Ethernet connection) is allocated to the Logical Port num-
ber that you selected.