Technical Data

SMA Solar Technology AG

74

SMC6-8TL-IEN101040

Installation Guide

11 Technical Data

11.1 Sunny Mini Central 6000TL

DC Input

* The maximum open circuit voltage, which can occur at a cell temperature of -10 °C, may not exceed the maximum input voltage.

AC Output

Maximum DC power at cos ϕ = 1

P

DC

6,200 W

Maximum DC voltage *

U

DC

max

700 V

MPP voltage range

U

PV

333 V … 500 V

DC nominal voltage

U

DC nom

350 V

Minimum DC voltage

U

DC min

330 V

Start voltage, adjustable

U

PV Start

400 V

Maximum input current

I

PV max

19.0 A

Number of MPP trackers

1

Maximum number of parallel strings

4

Voltage ripple of input voltage

U

pp

< 10 %

Internal consumption during operation

< 10 W

AC nominal power at 230 V AC, 50 Hz

P

AC nom

6,000 W

Maximum AC apparent power

S

AC max

6,000 VA

Nominal AC current

I

AC nom

27 A

Maximum output current

I

AC max

27 A

Maximum fuse protection

50 A

Harmonic distortion of output current at
AC T

HD

voltage < 2 %,

AC power > 0.5 AC nominal power

K

IAC

< 3 %

Nominal AC voltage

U

AC nom

220 V / 230 V / 240 V

AC voltage range

U

AC

180 V … 260 V

AC grid frequency

f

AC nom

50 Hz / 60 Hz

Operating range at AC grid frequency

f

AC

50 Hz: 45.5 Hz … 54.5 Hz
60 Hz: 55.5 Hz … 64.5 Hz

Power factor at nominal AC power

cos ϕ

1

Supply phases

1

Connection phases

1

Overvoltage category as per
AUS/NZS 60950.1:2003

II

Overvoltage category as per EN 50178:1998

III