11 technical data, 1 sunny mini central 6000tl, Technical data – SMA SMC 6000TL Installation User Manual
Page 74: Sunny mini central 6000tl
Technical Data
SMA Solar Technology AG
74
SMC6-8TL-IEN101040
Installation Guide
11 Technical Data
11.1 Sunny Mini Central 6000TL
DC Input
* The maximum open circuit voltage, which can occur at a cell temperature of -10 °C, may not exceed the maximum input voltage.
AC Output
Maximum DC power at cos ϕ = 1
P
DC
6,200 W
Maximum DC voltage *
U
DC
max
700 V
MPP voltage range
U
PV
333 V … 500 V
DC nominal voltage
U
DC nom
350 V
Minimum DC voltage
U
DC min
330 V
Start voltage, adjustable
U
PV Start
400 V
Maximum input current
I
PV max
19.0 A
Number of MPP trackers
1
Maximum number of parallel strings
4
Voltage ripple of input voltage
U
pp
< 10 %
Internal consumption during operation
< 10 W
AC nominal power at 230 V AC, 50 Hz
P
AC nom
6,000 W
Maximum AC apparent power
S
AC max
6,000 VA
Nominal AC current
I
AC nom
27 A
Maximum output current
I
AC max
27 A
Maximum fuse protection
50 A
Harmonic distortion of output current at
AC T
HD
voltage < 2 %,
AC power > 0.5 AC nominal power
K
IAC
< 3 %
Nominal AC voltage
U
AC nom
220 V / 230 V / 240 V
AC voltage range
U
AC
180 V … 260 V
AC grid frequency
f
AC nom
50 Hz / 60 Hz
Operating range at AC grid frequency
f
AC
50 Hz: 45.5 Hz … 54.5 Hz
60 Hz: 55.5 Hz … 64.5 Hz
Power factor at nominal AC power
cos ϕ
1
Supply phases
1
Connection phases
1
Overvoltage category as per
AUS/NZS 60950.1:2003
II
Overvoltage category as per EN 50178:1998
III