53

4. Release all DC plug connectors with the help of a

screwdriver:
– Insert a screwdriver into one of the side slits (1).
– Lever the screwdriver upward (2) and pull out

the plug connector (3).

DANGER!
Danger to life due to high voltages in the inverter.

A secure separation from the PV generator is only guaranteed after pulling off the
Electronic Solar Switch and all DC plug connectors.

• Remove all DC plug connectors to

completely disconnect the PV generator
from the inverter.

DANGER!
Danger to life due to high voltages in the inverter.

The capacitors in the inverter require 5 minutes to discharge.

• Wait 5 minutes before opening the inverter.