beautypg.com

Configuration options – SMA SMC 6000TL Installation User Manual

Page 38

background image

Electrical Connection

SMA Solar Technology AG

38

SMC6-8TL-IEN101040

Installation Guide

Configuration Options

There are 4 different configuration options for the "PowerBalancer" parameter.

• FaultGuard

This operating mode enables the implementation of three-phase grid voltage monitoring that
also reacts to device failures.
– If one of the three inverters indicates a grid voltage fault and stops feeding in, the other

two inverters also disconnect from the grid immediately.

– If one of the three inverters indicates a device fault and stops feeding in, the other two

inverters also disconnect from the grid 5 minutes later.

Local connection requirements
Select the respective setting and always observe the local connection requirements and
provisions of your utility operator.