9 failure search, 1 blink codes, 2 error messages – SMA SMC 6000TL Installation User Manual
Page 61: Failure search, Blink codes, Error messages, 1 blink codes 9.2 error messages

SMA Solar Technology AG
Failure Search
Installation Guide
SMC6-8TL-IEN101040
61
9 Failure Search
If the inverter displays other blink codes or error messages other than those described in the following
section, contact the SMA Serviceline
In the user manual provided, you will also find a description of the display messages during operation,
the status messages and measuring channels.
Do not try to carry out repairs other than those described here. Instead, use the SMA Solar
Technology AG 24-hour replacement service (the inverter will be ready for dispatch within 24 hours
and sent to a forwarding agency) and repair service
9.1 Blink Codes
9.2 Error Messages
When a disturbance occurs, the inverter generates a message, which depends on the operating mode
and the type of disturbance detected.
Green
Red
Yellow
Status
Glows continuously
Is not glowing
Is not glowing
OK (feeding operation)
Glows continuously
Is not glowing
Ground fault or varistor
defective
Glows continuously
OK (initialization)
Flashes quickly
(3 x per second)
Is not glowing
Is not glowing
OK (stop)
Glows continuously
Is not glowing
Ground fault or varistor
defective
Flashes slowly
(1 x per second)
Is not glowing
Is not glowing
OK (waiting, grid
monitoring)
Briefly goes out
(approx. 1 x per
second)
Glows continuously
Is not glowing
Ground fault or varistor
defective
Is not glowing
Is not glowing
OK (derating)
Is not glowing
Is not glowing
Is not glowing
OK (disconnection)
Glows / flashes
Disturbance
Glows continuously
Is not glowing
Ground fault or varistor
defective
Glows / flashes
Ground fault or varistor
defective and disturbance