switch the data acquisition of Sunny Boy Control off:
"
Setup
Setup
Setup
Setup - System - Service Funct.: reset system
- System - Service Funct.: reset system
- System - Service Funct.: reset system
- System - Service Funct.: reset system
". Confirm twice,
the Sunny Boy Control A will start the Plug & Play sequence the next time it is
activated.
•
start "
Device Detection
Device Detection
Device Detection
Device Detection
" on the PC with Sunny Data and detect the Sunny
Boy Control.
•
connect Sunny Boy Control A to the furthest away socket you want to connect
participants to. Define the Sunny Boy Control A to be communication test
participant in the "
Setup - Diagnosis - Communication
Setup - Diagnosis - Communication
Setup - Diagnosis - Communication
Setup - Diagnosis - Communication
" menu.
•
Sunny Data version 1.30 and higher supports "'Dev Com Statistics'"
Acceptable data transmission quality is given with 75 % and more.
Testing the Communication to the Sunny Boys
"
Setup - Diagnosis - Communication
Setup - Diagnosis - Communication
Setup - Diagnosis - Communication
Setup - Diagnosis - Communication
" helps you detect transmission failures
to single devices. Select the device that you want to test:
[COMMUNICATION ]
01: WR700-08
ß
Device ID: Device Type
02: WR700-08
03: WR700-07
04: WR700-07
Fig. 7.11: Selecting a Device
The Sunny Boy Control Light then sends data inquiries to the selected device and
evaluates the transmission quality.
[02:COMMUNICAT.]
[Device ID: Device Type]
OK 99%
ß
percentage of tolerably transmitted packets
Pakets 10233
Errors 123
Fig. 7.12: Communication test