beautypg.com

Communication, Communicat, Ok 99 – SMA Sunny Boy Control Light User Manual

Page 82: Errors 123

background image

Sunny Boy Control Light

Chapter 7: Appendix

SUNBCL-11:NE

- 82 -

SMA Regelsysteme GmbH

switch the data acquisition of Sunny Boy Control off:

"

Setup

Setup

Setup

Setup - System - Service Funct.: reset system

- System - Service Funct.: reset system

- System - Service Funct.: reset system

- System - Service Funct.: reset system

". Confirm twice,

the Sunny Boy Control A will start the Plug & Play sequence the next time it is

activated.

start "

Device Detection

Device Detection

Device Detection

Device Detection

" on the PC with Sunny Data and detect the Sunny

Boy Control.

connect Sunny Boy Control A to the furthest away socket you want to connect

participants to. Define the Sunny Boy Control A to be communication test

participant in the "

Setup - Diagnosis - Communication

Setup - Diagnosis - Communication

Setup - Diagnosis - Communication

Setup - Diagnosis - Communication

" menu.

Sunny Data version 1.30 and higher supports "'Dev Com Statistics'"

Acceptable data transmission quality is given with 75 % and more.

Testing the Communication to the Sunny Boys

"

Setup - Diagnosis - Communication

Setup - Diagnosis - Communication

Setup - Diagnosis - Communication

Setup - Diagnosis - Communication

" helps you detect transmission failures

to single devices. Select the device that you want to test:

[COMMUNICATION ]

ˆ01: WR700-08

ß

Device ID: Device Type

02: WR700-08

03: WR700-07 Š

04: WR700-07

Fig. 7.11: Selecting a Device

The Sunny Boy Control Light then sends data inquiries to the selected device and

evaluates the transmission quality.

[02:COMMUNICAT.]

[Device ID: Device Type]

‡OK… 99%

ß

percentage of tolerably transmitted packets

Pakets… 10233

Errors… 123

Fig. 7.12: Communication test