The Sunny Boy Control Light saves the data of the PV-plant of up to the

last 200 days. After this the oldest data is overwritten. Save the data to a

PC regularly in order to obtain a continuous overview of your PV-plants

performance.

4.3.2 Spot

Values

The function "

Spot Values

Spot Values

Spot Values

Spot Values

" enables to show all accessible values of every single

device. At first you will enter the following dialog, in which you may see the present

state of every single device.

[ SPOT VALUES ]

[ Pac/W Status ]

ˆ„SC… 2k operat

ß

Device ID, current power (here 2 kW), status

„01… 0 Stop Š

„02… 120 MPP

ß

Device ID, current power (here 120 W), status

„03… 0 Stop

„17… 210 MPP

Fig. 4.7: Device selection for Spot Value display

Select a device with

[[[[

Enter

]]]]

and all current values acquired in this device are

displayed. Scroll through the list with the

[[[[↑↑↑↑]]]]

and

[[[[↓↓↓↓]]]]

keys.

[01:SPOT VALUES]

[Device ID: Spot Values]

‡Spot Time…

… 14:11.00

Vpv… Š

……236.00V

Vpv-Setpoint…

……299.00V

Status

Mpp

Failure

------

Fig. 4.8: Display of Spot Values for selected device