beautypg.com

Failure, Communication, Ok-total 57 – SMA Sunny Boy Control Light User Manual

Page 36

background image

Sunny Boy Control Light

Chapter 4: Working with the Sunny Boy Control Light

SUNBCL-11:NE

- 36 -

SMA Regelsysteme GmbH

All events with a "

ˆ

" (filled arrow) in the beginning have additional information in the

detailed view. Select the event and press [ENTER].

[ FAILURE ]

[ 01: WR15-005 ]

[Device ID: Device Type]

Communication…

ß

Details on failure

…OK-total 57%

Fig. 4.15: Details on failure

[ESC] exits the detailed view of the logged event.

Summary of all Events

Event Type

Description

Startup

Status

Power on / system startup

Time Changed

Status

Time or date was changed by user

Failure Conf.

Status

The user confirmed a failure or warning

System Reset

Warning

System was restarted after a failure

Device Failure

Warning

A connected device reported a failure

Offline

Warning

A connected device does not reply

CommSpot20

Warning

Communication is partially disturbed

Communication

Failure

Communication is disturbed over a longer time

Yield

Warning

Energy yield of a single device is below threshold

24h Offline

Failure

Device was offline for longer than 24 hours

FAX Plant-Inf.

Status

FAX PV-plant info was sent

FAX Error/War.

Status

FAX failure warning fax was sent

FAX Retry

Warning

FAX transmission failure

FAX Error

Failure

FAX transmission was not possible

Fig. 4.16: List of events