Chapter 5: Menu Functions for Configuration
SUNBCL-11:NE
- 44 -
SMA Regelsysteme GmbH
The channel selection and the numeric format for the HvG, Siebert and
DATALITE cannot be changed.
Sunny Boy Control detects a connected PC. So the port need not be
stopped for operation with an external display. If there are no requests for
60s the Sunny Boy Control sends Display-Data to COM2.
HvG and Siebert
Definition of the ASCII string:
Start E-Total
[kWh]
E-today
[kWh]
Pac
[kW]
Iac-Ist
[A]
Upv-Ist
[V]
Uac
[V]
E-today
[Wh]
End
(Siebert)
#
LLLLLL
LLLL LLRR LLRR LLLL LLLL LLLL CR,LF
L = left of the decimal point R = right of the decimal point
The ASCII string is sent with 2400 Baud (no parity, 8 bit, 1 stop bit) on the port ‘PC
(COM 2)’ and is updated regularly.
Example for the ASCII string
The string ‘#001104001802470314018902301827’
results in the following data to be displayed:
Start E-Total
[kWh]
E-today
[kWh]
Pac
[kW]
Iac-Ist
[A]
Upv-Ist
[V]
Uac
[V]
E-today
[Wh]
End
(Siebert)
Value
1104
18
2,47
3,14
189
230
1827
ASCII #
001104 0018
0247 0314
0189
02
30
1827
CR,LF
EnergieCom
Selecting EnergieCom as type results in various configuration possibilities. Measured
values of the
Sunny Boy
Control Light and the registered Sunny Boys can be
displayed. Up to 99 different displays can be generated in EnergieCom format. The
number of the display is the same as the two address bytes in the serial telegram.
Examples are given in Fig. 5.17.