Example datalite display – SMA Sunny Boy Control Light User Manual
Page 51
Sunny Boy Control Light
Chapter 5: Menu Functions for Configuration
SUNBCL-11:NE
- 51 -
SMA Regelsysteme GmbH
Example DATALITE Display
Telegram (Hex)
Meaning / Display
01 20 1C
Start, Controller-Address, Field Separator
30 41 6B 74 75 65 6C 6C 3A 1C
Power:
31 20 20 20 20 36 35 34 20 57 20 1C
654 W
32 48 65 75 74 65 3A 1C
Today:
33 20 20 20 34 2E 31 36 20 6B 57 68 1C
4.16 kWh
34 47 65 73 61 6D 74 3A 1C
Total:
35 20 20 32 34 31 37 37 20 6B 57 68 1C
24177 kWh
36 44 61 74 75 6D 3° 20 20 25 44 2E 25 4D 2E 25 59 1C
Date:
%D.%M.%Y
37 5A 65 69 74 3A 20 20 20 25 48 3A 25 6D 3A 25 53 1C
Time:
%H:%m:%S
16 0D 01 30 1C
Synchronisation
0D
End (CR)
Example for setting the internal time
at 30/11/1999 14:18:58
Telegramm (Hex)
Meaning
01 7F 1C
Start, Controller-Address, FS
1B 54
Adjust Real-Time-Clock
33
Year 1999: x33 = d51 = d99 + d32 – d80
2B
Month 11: x2B = d43 = d11 + d32
20
No
3E
Day 30: x2E = d62 = d30 + d32
2E
Hour 14: x2E = d46 = d14 + d32
32
Minute 18: x32 = d50 = d18 + d32
5A
Second 58: x5A = d90 = d58 + d32
0D End
Further details are available in the user manual of the display and on the internet