beautypg.com

Tolerances, Warnings, 15min – SMA Sunny Boy Control Light User Manual

Page 58: Offline, 30min, Energy, Communication

background image

Sunny Boy Control Light

Chapter 5: Menu Functions for Configuration

SUNBCL-11:NE

- 58 -

SMA Regelsysteme GmbH

[ TOLERANCES ]

‡Warnings…

………………15min

Offline… Š

………………30min

Energy…

………………50%

Communication…

………………50%

Fig. 5.34: Definition of the thresholds for the "Control"

"

Warnings

Warnings

Warnings

Warnings

" defines how long the failure must be occurring before a warning is

generated by the Sunny Boy Control Light.

"

Offline

Offline

Offline

Offline

" defines the maximum period of time a device may be off-line before a

warning is generated. (This is based on the entire operating time of the plant as

"online time" of the first device and the shutdown of the last device). The minimal

time is 15 minutes.

"

Energy

Energy

Energy

Energy

" defines the deviation of a single device from the average yield of the entire

plant in percent. Be generous with this parameter (or let’s say more tolerant, as it is in

the tolerance menu) due to the fact that there are always slight deviations resulting

from different panels, panel geometry and temperature. See the below example for

details. And note that the "

energy

energy

energy

energy

" controlling function naturally does not make

sense for plants with only one Sunny Boy Inverter since single inverters in a PV-plant

with only one inverter simply do not deviate from the average of the entire plant.

0% deactivates the "

Energy

Energy

Energy

Energy

" controlling function.

The following example is a PV-plant with 4 inverters (A, B, C and D)

with a defined tolerance of 90%: