beautypg.com

SMA Sunny Boy Control Light User Manual

Page 47

background image

Sunny Boy Control Light

Chapter 5: Menu Functions for Configuration

SUNBCL-11:NE

- 47 -

SMA Regelsysteme GmbH

configured. [ESC] leaves the menu. All changes must be confirmed in order to take

effect.

The following example shows the first 6 displays while the default values are used for

device, channel and format.

Display Device:Channel Format EnergieCom

Display

01 SC:Pac

4.0

7

02 SC:E-total

4.0

4

8

2

8

03 SC:E-today

4.0

2

3

04 SC:Pac

6.2

6. 5

4

05 SC:E-total

6.2

4

8

2

8. 4

7

06 SC:E-today

6.2

2

3. 3

5

Fig. 5.19: Example for EnergieCom displays

Zeros on the left are not displayed.

The unit for Pac always is kW (even when the unit on the

Sunny Boy

Control

Light is “Watt”). Display in Watt is done by setting the format to “4.3”.

Too large numbers are indicated with “o.Error” (overflow).

The ASCII string is sent via port ‘PC (COM 2)’ (8, 1, N).

Example

05B@@482847 results in the following hexadecimal output

02 30 35 42 40 40 34 38 32 38 34 37 03

Start Address

Format

P1 P2 P3

Value End

Hex

02

30 35

42 40 40

34 38 32 38 34 37

03

ASCII

0 5

B @ @

4 8 2 8 4 7

Description

Display 05

Point at digit 4

4828,47