Sunny Boy Control Light

Chapter 5: Menu Functions for Configuration

SUNBCL-11:NE

- 59 -

SMA Regelsysteme GmbH

Device Yield Warning

Remarks

A

2,2 kWh

none

The device is operating optimally

B

1,7 kWh

failure

Yield is below the tolerated value -> warning

C

0 kWh

offline

Device is offline

D

2,1 kWh

none

The device is operating optimally

total 6,0

kWh

average

2,0 kWh

Average computed from the active inverters

tolerance

1,8 kWh

Minimum yield for not generating a warning

Fig. 5.35: Tolerancing 4 Sunny Boy inverters

Inverters that are offline do not influence the calculation of the average

yield.

Communication

Communication

Communication

Communication

defines the tolerable percentage of corrupt data packages.

5.5.2 FAX-Info

The Sunny Boy Control Light can send fax messages if desired. An external fax-

modem must be installed on the COM2:PC port.

Sunny Boy Sunny Boy

Sunny Boy

Sunny Boy

Control Light

Powerline Mains Communication

RS 232

telephone line

modem

Fig. 5.36: Schematic cabling of the fax-modem connection

A detailed description of the connection of the modem is in the "Installation Guide".

"

FAX-Info

FAX-Info

FAX-Info

FAX-Info

" activates / deactivates the Fax message function: