2 position of the mounting holes on the inverter, 3 drilling mounting holes in the foundation – SMA SC 500CP-US User Manual
Page 42

6 Preparation for Installation
SMA America, LLC
42
SCCP-US-IA-US_en-41
Installation Manual
6.3.2 Position of the Mounting Holes on the Inverter
There are six mounting holes in the base area of the inverter for fixing it to the foundation. In addition, you can use the
two outer mounting brackets.
Figure 24: Position of the mounting holes on the inverter
The diameter of the mounting holes is
5
⁄
8
in. (16 mm).
6.3.3 Drilling Mounting Holes in the Foundation
1. Measure the distance for the drill holes.
2. Mark the positions of the drill holes.
3. Drill mounting holes at the positions marked in the foundation (diameter 0.62 in. (16 mm)).
Clearance between
Clearance
Mounting holes 1 and 2
53.03 in. (1,347 mm)
Mounting holes 2 and 3
39.37 in. (1,000 mm)
Mounting holes 3 and 4
31.69 in. (805 mm)
Mounting holes 4 and 5
39.37 in. (1,000 mm)
Mounting holes 5 and 6
53.03 in. (1,347 mm)
Mounting holes 1 and 6
31.69 in. (805 mm)
Outer mounting holes
31.30 in. (795 mm)