2 sunny boy 3800-us, Sunny boy 3800-us – SMA SB 3000-US User Manual
Page 92
12 Technical Data
SMA America, LLC
92
SB30-40-US-IA-en-34
Installation Manual
12.1.2 Sunny Boy 3800-US
DC input
AC output
Efficiency
Maximum MPP voltage at 240 V nominal value
250 V to 480 V
Input operating voltage range
250 V to 600 V
Maximum PV array input power
5,000 W
Maximum DC power
4,250 W
DC starting voltage
285 V
Maximum DC input current
18 A
Maximum short-circuit current
25 A
DC voltage ripple
˂ 10%
AC operating voltage range at 240 V nominal value
211 V to 264 V
AC operating frequency range
59.3 Hz to 60.5 Hz
AC frequency, nominal value
60 Hz
Maximum continuous AC output power
3,800 W
Total harmonic factor of the output current with total
harmonic factor of the AC voltage ˂ 2%
and AC power ˃ 50% rated power
˂ 4%
Maximum continuous AC output current at 240 V
16 A
Maximum residual output current
30 A
Maximum output overcurrent protection
30 A
Maximum backfeed current from the power distribution
grid to the PV array
30 A AC
Synchronization of inrush current
8 A
Tripping limit accuracy
− 2% to +2%
Tripping time accuracy
− 0.1% to +0.1%
Power factor at nominal power
1
Inverter peak efficiency
96.8%
CEC efficiency at 240 V nominal value
96.0%