4 display messages, 1 status messages, Display messages – SMA SB 3000-US User Manual
Page 73: Status messages
SMA America, LLC
10 Troubleshooting
Installation Manual
SB30-40-US-IA-en-34
73
10.4 Display messages
10.4.1 Status Messages
Message
Explanation
Derating
Reduction of the power fed into the power distribution grid due to high
heat sink temperatures
Disturbance
Displays an error status that concerns the power distribution grid. This error
status resolves itself.
Error
Error status that must be rectified
Grid monitoring
When the system starts, the inverter performs a synchronization with the
power distribution grid.
MPP
The inverter is in MPP mode.
The inverter adjusts the input voltage and the input current from the PV
array in order to achieve the highest possible DC output power.
MPP-Search
When the system starts, the inverter tests the MPP tracking range.
Offset
When the system starts, the inverter performs an offset calibration of the
electronics.
Stop
The inverter has been manually set to system stop.
Turbine
The inverter is in turbine mode.
This operating mode is specifically conceived for use with wind turbine
systems.
V-Const
The input voltage of the PV array is set at a given target value and the
inverter is not operating in MPP mode.
This operating mode is suitable for using the inverter with fuel cells or small
hydroelectric power plants.
Wait
DC voltage is not high enough to start.
Warning
Error status that requires an additional inspection