14.4 Climatic Conditions

Extended temperature range

−25°C to +60°C

(−13°F to +140°F)

Extended humidity range

0% to 100%

Extended air pressure range

 79.5 kPa to 106 kPa

14.5 Equipment

DC connection

Screw terminals

AC connection

Spring-cage terminal

SMA Webconnect Data Module

RJ45, as standard

14.6 Torques

Upper enclosure lid screws

6.0 Nm (53 in-lb)

Lower enclosure lid screws

2.0 Nm (17.7 in-lb)

Screws for DC protective cover

3.5 Nm (31 in-lb)

Screw for grounding

5,8 Nm (51 in-lb)

Screw terminal DC input

5.0 Nm (44 in-lb)

14.7 Data Storage Capacity

Energy yields in the course of the day

63 days

Daily yields

30 years

Event messages for users

250 events

Event messages for installers

250 events