3 g1_xist1 preset control, 4 scaling function control, Table 33 g1_xist1 preset control – HEIDENHAIN PROFINET User Manual
Page 70: Table 34 scaling function control, G1_xist1 preset control, Scaling function control, Table 33, Table 34

Functional description of the encoder
70
7.3
G1_XIST1 Preset control
This parameter controls the effect of a preset on the G1_XIST1
If Class 4 functionality is activated and G1_XIST1 Preset control is
disabled, the position value in G1_XIST1 will not be affected by a
G1_XIST1 is affected by a preset com-
mand
Preset does not affect G1_XIST1
functionality parameter is disabled.
7.4
Scaling function control
This parameter enables or disables the Scaling function of the en-
Note: The parameter Class 4 functionality must be enabled