3 base mode parameter access, 1 general characteristics, 2 parameter requests and responses – HEIDENHAIN PROFINET User Manual
Page 53: 3 changing the preset value, Table 23 changing the preset value, Db4 is the instance data block of sfb, Base mode parameter access, General characteristics, Parameter requests and responses, Changing the preset value
Acyclic Parameter Data
53
6.3
Base mode parameter access
The PROFIdrive parameters and the encoder parameter 65000
can be accessed by the Acyclic Data Exchange service using the
Base Mode Parameter access local (Record Data Object 0xB02E).
6.3.1
General characteristics
Acyclic parameter can be transmitted 1(single) or up to 39 (multi)
in one access. A parameter access can be up to 240 bytes long.
6.3.2
Parameter requests and responses
Request ID, DO-ID and number of parameters of the access.
One address for each parameter, if several parameters are ac-
If the Request ID is 0x02 (change value) the value is set in the re-
quest and if the Request ID is 0x01 (request value), the value ap-
6.3.3
Changing the preset value
Table 23 below shows the structure of a change value request.
Write of Preset value, parameter 65000
0x02 Change value, 0x01read value
Format
0x04
Data type integer 32
Number of values
0x01
Table 25
Changing the preset value