Operating time, Offset value, Table 32 – HEIDENHAIN PROFIBUS-DP (DPV0) User Manual

Page 54: Diagnostics, software version, Table 33, Diagnostic, operating time

background image

Encoder and Gateway functionality, DPV0

54

DDLM_Slave_Diag

Octet

26

27

Bits

15-8

7-0

Data

2

7

-2

0

2

7

-2

0

Revision number

Index

Software Version

Table 32

Diagnostics, software version



5.6.13

Operating time

The operating time monitor stores the operating time for the

device in operating hours. The operating time is saved every six

minutes in the non-volatile memory in the device. This happens

as long as the device is under power. The operating time is

displayed as a 32-bit value without sign in 0.1 h by the

DDLM_Slave_Diag function.If the operating time function is

not supported by the device, it is set to the maximum value

(FFFF FFFF hex).

DDLM_Slave_Diag

Octet

28

29

30

31

Bits

31-24

23-16

15-8

7-0

Data

2

31

-2

24

2

23

-2

16

2

15

-2

8

2

7

-2

0

Operating time

Table 33

Diagnostic, operating time