Normal operation (DDLM_Data_Exchange mode)

In the normal mode (DDLM_Data_Exchange mode), data are

exchanged between master and slaves. The preset function can

be carried out only in this operating mode. The data exchange is

described in chapter 5.5.

5.3

Configuration, DPV0

The configuration of a DPV0 device is conducted by choosing

encoder class, i.e. setting the input/output data structure. The
configuration options are 16-bit, 32-bit or 32-bit + 16-bit

velocity input data, for explanation view chapter 4.1.

5.4

Parameterization, DPV0

The PROFIBUS-DPV0 device is parameterized by means of
the operating parameters. The values selected in the

configuration tool are saved in the DP master and are
transferred to the PROFIBUS-DP slave each time the network

is started. The following table lists all available parameters:

Parameters

Data type

Parameter
octet number

Device
class

Code sequence

Bit

9

1

Class 2 functionality

Bit

9

2

Commissioning diagnostics

Bit

9

Optional

Scaling function control

Bit

9

2

Measuring units per revolution

Unsigned 32 bits

10-13

2

Total measuring range in

measuring units

Unsigned 32 bits

14-17

2

Manufacturer specific functions

Bit

26-28

Optional

Velocity control

2 bit

39

2.ext

Table 11

Operating parameters in DPV0