5.2.3
Normal operation (DDLM_Data_Exchange mode)
In the normal mode (DDLM_Data_Exchange mode), data are
exchanged between master and slaves. The preset function can
be carried out only in this operating mode. The data exchange is
described in chapter 5.5.
5.3
Configuration, DPV0
The configuration of a DPV0 device is conducted by choosing
encoder class, i.e. setting the input/output data structure. The
configuration options are 16-bit, 32-bit or 32-bit + 16-bit
velocity input data, for explanation view chapter 4.1.
5.4
Parameterization, DPV0
The PROFIBUS-DPV0 device is parameterized by means of
the operating parameters. The values selected in the
configuration tool are saved in the DP master and are
transferred to the PROFIBUS-DP slave each time the network
is started. The following table lists all available parameters:
Parameters
Data type
Parameter
octet number
Device
class
Code sequence
Bit
9
1
Class 2 functionality
Bit
9
2
Commissioning diagnostics
Bit
9
Optional
Scaling function control
Bit
9
2
Measuring units per revolution
Unsigned 32 bits
10-13
2
Total measuring range in
measuring units
Unsigned 32 bits
14-17
2
Manufacturer specific functions
Bit
26-28
Optional
Velocity control
2 bit
39
2.ext
Table 11
Operating parameters in DPV0