Encoder and Gateway functionality, DPV0

47

5.6.3

Operating Status

Octet 9 in the diagnostic function provides information
about encoder-specific parameters. A class 2 encoder

sets the functionality bit for class 2 commands in order to
show the DP master that all class 2 commands are

supported. The DP master must activate the class 2
functionality bit in the parameter message (DDLM_Set_Prm)

to enable the use of class 2 functions. The status bit of
the scaling function is set when the scaling function is

activated and the resolution of the encoder is calculated
by means of the scaling parameters.

DDLM_Slave_Diag

Octet

9

Bits

7-0

Operating status

Bits

Definition

=0

=1

0

Code sequence

Increasing position

values for clockwise

revolutions (Seen from

flange side)

Increasing position

values for counter

clockwise revolutions

(Seen from flange side)

1

Class 2

functionality

No, not supported

Yes

2

Commissioning

diagnostics

No, not supported

Yes

3

Scaling function

status

Scaling disabled

Scaling enabled

4-7

Currently not assigned

Table 23

Operating status