beautypg.com

Functions in touch probe cycles – HEIDENHAIN TNC 620 (73498x-02) ISO programming User Manual

Page 411

background image

Using 3-D touch probes (Touch Probe Function software option) 14.6

14

TNC 620 | User's Manual for DIN/ISO Programming | 5/2013

411

Functions in touch probe cycles

Soft keys that are used to select the probing direction or a probing
routine are displayed in the manual touch probe cycles. The soft
keys displayed vary depending on the respective cycle:

Soft key

Function

Select the probing direction

Capture the actual position

Probe hole (inside circle) automatically

Probe stud (outside circle) automatically

Automatic probing routine for holes and studs

If you use a function for probing a circle
automatically, the TNC automatically positions
the touch probe to the respective touch points.
Ensure that the positions can be approached without
collision.

If you use a probing routine for probing a hole or a stud
automatically, the TNC opens a form with the required input fields.

Input fields in the

Measure stud and Measure hole forms

Input field

Function

Stud diameter? or Hole

diameter?

Diameter of probe contact (optional
for holes)

Safety clearance?

Distance to the probe contact in
the plane

Incr. clearance height?

Positioning of touch probe in
spindle axis direction (starting from
the current position)

Starting angle?

Angle for the first probing
operation (0° = Positive direction of
principal axis, i.e. in X+ for spindle
axis Z). All other probe angles
result from the number of touch
points.

Number of touch

points?

Number of probing operations (3 to
8)

Angular length?

Probing a full circle (360°)
or a circle segment (angular
length<360°)