Editing the table format – HEIDENHAIN TNC 620 (73498x-02) ISO programming User Manual
Page 332
Programming: Special functions
11.5
Freely definable tables
11
332
TNC 620 | User's Manual for DIN/ISO Programming | 5/2013
Editing the table format
Press the EDIT FORMAT soft key (2nd soft-key level): The TNC
opens the editor form, in which the table structure is shown.
The meanings of the structure commands (header entries) are
shown in the following table.
Structure
command
Meaning
Available
columns:
List of all columns contained in the
table
Move before:
The entry highlighted in
Available
columns is moved in front of this
column
Name
Column name: Is displayed in the
header
Column type
TEXT: Text entry
SIGN: Sign + or -
BIN: Binary number
DEC: Decimal, positive, complete
number (cardinal number)
HEX: Hexadecimal number
INT: Complete number
LENGTH: Length (is converted in inch
programs)
FEED: Feed rate (mm/min or 0.1 inch/
min)
IFEED: Feed rate (mm/min or inch/min)
FLOAT: Floating-point number
BOOL: Logical value
INDEX: Index
TSTAMP: Fixed format for date and time
Default value
Default value for the fields in this
column
Width
Width of the column (number of
characters)
Primary key
First table column
Language-
sensitive column
name
Language-sensitive dialogs