beautypg.com

11 preassigned q parameters, Values from the plc: q100 to q107, Active tool radius: q108 – HEIDENHAIN TNC 620 (73498x-02) ISO programming User Manual

Page 290: Tool axis: q109, Preassigned q parameters

background image

Programming: Q Parameters

9.11

Preassigned Q parameters

9

290

TNC 620 | User's Manual for DIN/ISO Programming | 5/2013

9.11

Preassigned Q parameters

The Q parameters Q100 to Q199 are assigned values by the TNC.
The following types of information are assigned to Q parameters:

Values from the PLC

Tool and spindle data

Data on operating status

Results of measurements from touch probe cycles etc.

The TNC saves the values for the preassigned Q parameters Q108,
Q114 and Q115 to Q117 in the unit of measure used by the active
program.

Do not use preassigned Q parameters (or QS
parameters) between

Q100 and Q199 (QS100 and

QS199) as calculation parameters in NC programs.
Otherwise you might receive undesired results.

Values from the PLC: Q100 to Q107

The TNC uses the parameters Q100 to Q107 to transfer values
from the PLC to an NC program.

Active tool radius: Q108

The active value of the tool radius is assigned to Q108. Q108 is
calculated from:

Tool radius R (tool table or

G99 block)

Delta value DR from the tool table

Delta value DR from the

T block

The TNC remembers the current tool radius even if
the power is interrupted.

Tool axis: Q109

The value of Q109 depends on the current tool axis:

Tool axis

Parameter value

No tool axis defined

Q109 = –1

X axis

Q109 = 0

Y axis

Q109 = 1

Z axis

Q109 = 2

U axis

Q109 = 6

V axis

Q109 = 7

W axis

Q109 = 8