18 .1 gener a l user par a met e rs – HEIDENHAIN iTNC 530 (60642x-03) ISO programming User Manual
Page 608

608
Tables and overviews
1
8
.1 Gener
a
l user par
a
met
e
rs
Rapid traverse for triggering touch probes
MP6150
1 to 300 000 [mm/min]
Pre-positioning at rapid traverse
MP6151
Pre-position with speed from MP6150: 0
Pre-position at rapid traverse: 1
Measuring center misalignment of the
stylus when calibrating a triggering touch
probe
MP6160
No 180° rotation of the touch probe during calibration: 0
M function for 180° rotation of the touch probe during calibration: 1 to 999
M function for orienting the infrared sensor
before each measuring cycle
MP6161
Function inactive: 0
Orientation directly through the NC: –1
M function for orienting the touch probe: 1 to 999
Angle of orientation for the infrared sensor
MP6162
0 to 359.9999 [°]
Difference between the current angle of
orientation and the angle of orientation set
in MP 6162; when the entered difference is
reached, an oriented spindle stop is to be
carried out
MP6163
0 to 3.0000 [°]
Automatic operation: Automatically orient
the infrared sensor before probing to the
programmed probing direction
MP6165
Function inactive: 0
Orient infrared sensor: 1
Manual operation: Compensate the probe
direction taking an active basic rotation into
account
MP6166
Function inactive: 0
Take basic rotation into account: 1
Multiple measurement for programmable
probe function
MP6170
1 to 3
Confidence range for multiple
measurement
MP6171
0.001 to 0.999 [mm]
Automatic calibration cycle: Center of the
calibration ring in the X axis referenced to
the machine datum
MP6180.0 (traverse range 1) to MP6180.2 (traverse range 3)
0 to 99 999.9999 [mm]
Automatic calibration cycle: Center of the
calibration ring in the Y axis referenced to
the machine datum
MP6181.x (traverse range 1) to MP6181.2 (traverse range 3)
0 to 99 999.9999 [mm]
Automatic calibration cycle: Upper edge of
the calibration ring in the Z axis referenced
to the machine datum
MP6182.x (traverse range 1) to MP6182.2 (traverse range 3)
0 to 99 999.9999 [mm]
Automatic calibration cycle: Distance below
the upper edge of the ring where the
calibration is carried out by the TNC
MP6185.x (traverse range 1) to MP6185.2 (traverse range 3)
0.1 to 99 999.9999 [mm]
Touch probes