1 s w itc h -on, switc h -of f – HEIDENHAIN iTNC 530 (60642x-03) ISO programming User Manual
Page 469

HEIDENHAIN iTNC 530
469
14.1 S
w
itc
h
-on, switc
h
-of
f
The TNC is now ready for operation in the Manual Operation mode.
If your machine is equipped with absolute encoders, you 
can leave out crossing the reference marks. In such a 
case, the TNC is ready for operation immediately after the 
machine control voltage is switched on.
If your machine is equipped with incremental encoders, 
you can activate traverse range monitoring even before 
reference mark traverse by pressing the SW LIMIT 
MONITORING soft key. Your machine tool builder can 
provide this function axis-specifically. Remember that by 
pressing the soft key, traverse range monitoring is not 
necessarily active in all axes. The machine tool manual 
provides further information.
Ensure that you have referenced all axes before you start 
program run. Otherwise the TNC will stop machining as 
soon as it gets to an NC block with an axis that has not 
been referenced. 
The reference points need only be crossed if the machine 
axes are to be moved. If you intend only to edit or test 
programs, you can select the Programming and Editing or 
Test Run modes of operation immediately after switching 
on the control voltage. 
You can then traverse the reference points later by 
pressing the PASS OVER REFERENCE soft key in the 
Manual Operation mode..