7 Programming: Miscellaneous Functions

7.

6 Miscellaneous F

unctions f

o

r Laser Cut

ting Mac

h

ines

Output voltage as a function of time (time-
dependent ramp): M203

Behavior with M203

The TNC outputs the voltage V as a function of the time TIME. The
TNC increases or decreases the current voltage linearly to the value
programmed for V within the time programmed for TIME.

Input range

Effect

M203 remains in effect until a new voltage is output through M200,
M201, M202, M203 or M204.

Output voltage as a function of time (time-
dependent pulse): M204

Behavior with M204

The TNC outputs a programmed voltage as a pulse with a
programmed duration TIME.

Input range

Effect

M204 remains in effect until a new voltage is output through M200,
M201, M202, M203 or M204.

Voltage V:

0 to 9.999 Volt

TIME:

0 to 1.999 seconds

Voltage V:

0 to 9.999 Volt

TIME:

0 to 1.999 seconds