114

4 Fundamentals of NC, File Management, Programming Aids, Pallet Management

4.5 Cr

eating and W

riting Pr

ogr

a

ms

Functions for setting the feed rate

Soft key

Rapid traverse

Traverse feed rate automatically calculated in
TOOL CALL

Move at the programmed feed rate (unit of
measure is mm/min)

With FT, instead of a speed you define a time in
seconds (input range 0.001 to 999.999 seconds),
in which the programmed path is to be traversed.
FT

is effective only blockwise

With FMAXT, instead of a speed you define a time
in seconds (input range 0.001 to 999.999
seconds), in which the programmed path is to be
traversed. FMAXT is effective only for keyboards
with a rapid traverse potentiometer. FMAXT is
effective only blockwise

Functions for conversational guidance

Key

Ignore the dialog question

End the dialog immediately

Abort the dialog and erase the block