HEIDENHAIN iTNC 530 (340 422) User Manual
Page 10

10
Functions changed since the predecessor
versions 340420-xx and 340 421-xx
The datum shift in datum table function was changed. REF-based
datums are no longer available. Instead, the preset table was
introduced (see “DATUM SHIFT with datum tables (Cycle 7)” on
page 431)
The function of Cycle 247 was changed. Cycle 247 now activates a
preset from the preset table (see “DATUM SETTING (Cycle 247)”
on page 435)
Machine parameter 7475 is now meaningless (see “Compatibility
machine parameters for datum tables” on page 623)
The old fixed cycles 1, 2, 3, 4, 5, 17 and 18 were removed from he
soft-key structure and can therefore no longer be defined. Old
programs containing these cycles can still be run, however.
The Show blank in work space function was revised (see
“Showing the Workpiece in the Working Space” on page 596)
Automatic tool change after expiration of the tool life (M101) now
goes faster (see “Automatic tool change if the tool life expires:
M101” on page 166)
M116 now ignores swivel-head rotary axes (see “Feed rate in mm/
min on rotary axes A, B, C: M116 (software option 1)” on page 257)
In Cycles 251 to 254 the plunging behavior was changed. In vertical
plunging (Q366=0). the plunging angle ANGLE in the tool table must
now be set to =90°. Up to now, ANGLE had to be set to 0° for
vertical plunging. (see “Cycles for Milling Pockets, Studs and Slots”
on page 327)
In Cycles 251 to 254 the behavior for the finishing machining
operation (Q215=2) and oversize=0 (Q368/Q369) was changed.
(see “Cycles for Milling Pockets, Studs and Slots” on page 327)
The maximum number of tools in the tool table was reduced to
30 000 (see “Entering tool data in tables” on page 154)
The tool usage monitor was expanded by the capability of running
for a complete pallet (see “Dependent files” on page 593)