HEIDENHAIN TNC 426 (280 476) Pilot User Manual
Page 89

90
Digitizing
Digitizing Cycle RANGE (15)
Define the data transmission interface
TOUCH PROBE: Select Cycle 15 RANGE
PGM name for digitized data: Enter a name for the
NC program in which the digitized data should be stored.
Tch probe axis: Enter the axis of the touch probe
PGM name for range data: The name of the point table in
which the range is defined
MIN point TCH PROBE axis: The minimum point in the touch probe
axis
MAX point TCH PROBE axis: The maximum point in the
touch probe axis
Clearance height: Height at which the stylus cannot collide
with the model surface: Z
S
5 TCH PROBE 15.0 RANGE
6 TCH PROBE 15.1 PGM DIGIT.: DATA
7 TCH PROBE 15.2 Z PGM RANGE: TAB1
8 TCH PROBE 15.3 MIN:+0 MAX:+35 HEIGHT:+125