HEIDENHAIN TNC 426 (280 476) Pilot User Manual
Page 88
89
Digitizing
Digitizing Cycle RANGE (5)
Define the data transmission interface
TOUCH PROBE: Select Cycle 5 RANGE
PGM name for digitized data: Enter a name for the
NC program in which the digitized data should be stored.
Tch probe axis: Enter the axis of the touch probe
MIN. point range
MAX. point range
Clearance heigth: Height at which the stylus cannot collide
with the model surface: Z
S
5 TCH PROBE 5.0 RANGE
6 TCH PROBE 5.1 PGM NAME: DIGI1
7 TCH PROBE 5.2 Z X+0 Y+0 Z+0
8 TCH PROBE 5.3 X+100 Y+100 Z+20
9 TCH PROBE 5.4 HEIGHT: +100