beautypg.com

HEIDENHAIN TNC 426 (280 476) Pilot User Manual

Page 88

background image

89

Digitizing

Digitizing Cycle RANGE (5)

Define the data transmission interface

TOUCH PROBE: Select Cycle 5 RANGE

PGM name for digitized data: Enter a name for the

NC program in which the digitized data should be stored.

Tch probe axis: Enter the axis of the touch probe

MIN. point range

MAX. point range

Clearance heigth: Height at which the stylus cannot collide

with the model surface: Z

S

5 TCH PROBE 5.0 RANGE
6 TCH PROBE 5.1 PGM NAME: DIGI1
7 TCH PROBE 5.2 Z X+0 Y+0 Z+0
8 TCH PROBE 5.3 X+100 Y+100 Z+20
9 TCH PROBE 5.4 HEIGHT: +100