Program defaults for cycles

2.2

2

TNC 320 | User's Manual Cycle Programming | 3/2014

51

Global data for positioning behavior

Positioning behavior: Retraction in the tool axis at the end of
the machining step: Return to the 2nd set-up clearance or to the
position at the beginning of the unit

The parameters apply to each fixed cycle that you call
with the

CYCL CALL PAT function.

Global data for probing functions

Set-up clearance: Distance between stylus and workpiece
surface for automated approach of the probing position
Clearance height: The coordinate in the touch probe axis to
which the TNC traverses the touch probe between measuring
points, if the

Move to clearance height option is activated

Move to clearance height: Select whether the TNC moves
the touch probe to the set-up clearance or clearance height
between the measuring points

Applies to all Touch Probe Cycles 4xx.