CALIBRATE TS (Cycle 460, DIN/ISO: G460) 17.6

17

TNC 320 | User's Manual Cycle Programming | 3/2014

415

17.6

CALIBRATE TS (Cycle 460, DIN/ISO:
G460)

With Cycle 460 you can calibrate a triggering 3-D touch probe
automatically on an exact calibration sphere. You can do radius
calibration alone, or radius and length calibration.

1 Clamp the calibration sphere and check for potential collisions.

2 In the touch probe axis, position the touch probe over the

calibration sphere, and in the working plane, approximately over
the sphere center.

3 The first movement in the cycle is in the negative direction of

the touch probe axis.

4 Then the cycle determines the exact center of the sphere in the

touch probe axis.

Please note while programming:

HEIDENHAIN only gives warranty for the function of
the probing cycles if HEIDENHAIN touch probes are
used.